ZCV34/39/42

Zero Clearance Direct Vent Gas Fireplace

The ultimate in Zero Clearance Direct Vent Fireplaces for new home construction or renovation, and your best choice for installation anywhere throughout your home.

Standard Features

  • Millivolt or IPI valve system allows operation during a power failure with Hi/Low heat and flame adjustment
  • Safety Screen Barrier

Optional Features

Fan Kit

Heat activated with variable speed control

Picture Frame Surrounds

ZCV34 Surrounds
Hearth Mount 3” Wide (Covers 34 7/8” W x 30 3/4” H)
Picture Frame 4” Wide (Covers 36 5/6” W x 33 3/8” H)
Picture Frame 1 11/16” Wide (Covers 31 1/16” W x 28 3/4” H)

ZCV39 Surrounds
Hearth Mount 4” Wide (Covers 40 5/8” W x 35” H)
Picture Frame 4” Wide (Covers 40 5/8” W x 37” H)
Picture Frame 1 5/8” Wide (Covers 36 1/8” W x 32 1/2” H)

ZCV42 Surrounds
Hearth Mount 4” Wide (Covers 44 11/16” W x 38 1/8” H)
Picture Frame 4” Wide (Covers 44 11/16” W x 40 1/8” H)
Picture Frame 1 5/8” Wide (Covers 40 3/16” W x 35 5/8” H)

Glass Tray

Ember Glass (Bronze) – (ZCV39/42 only)

Accent Lighting

For use with the Glass Tray – (ZCV39/42 only)

Log Set

LOGF3 Log Set (ZCV39/42 only)
LOGC44 Log Set (ZCV34 only)

Porcelain Reflective Liner

Brick Refractory Liner

Traditional, Herringbone, Red Herringbone (ZCV39/42 only),
and Stacked (ZCV39/42 only)

Thermostat

Wall Mount Thermostat or Programmable Thermostat

Remote Control

Thermostat on/off, Thermostat on/off modulating, Thermostat on/off modulating and fan control

Vented Chase

Front Grill or Side Grills

Wall Mount Battery Holder (WMBH) :

The battery holder provides power to the IPI system in case of power failures. Locating the battery holder outside of the fireplace (wall mount), provides a convenient and accessible location for battery installation and removal.

 

 

ZCV34

Model Fuel Flue Gas Control Input Max. Input Min. FE (p.4.1-02)% Venting Viewing Area Glass Type Certification Actual Width (CVCK) Actual Height (CVCK) Actual Depth (CVCK) Actual Width (Louvers) Actual Height (Louvers) Actual Depth (Louvers) Power Vent
ZCV34N/ZCV34NE Natural Top Millivolt / IPI 19,000 BTU 13,500 BTU 53.49% / 56.14% 4”/7” Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 28 5/8" W x 25 3/8" H Tempered Heater 33” 36" 18 1/16” - - - Yes
ZCV34LP/ZCV34LPE Propane Top Millivolt / IPI 18,000 BTU 14,000 BTU 58.67% / 61.17% 4”/7” Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 28 5/8" W x 25 3/8" H Tempered Heater 33” 36” 18 1/16” - - - Yes
ZCV34NH/ZCV34NHE Natural Top Millivolt / IPI 19,000 BTU 13,500 BTU 63.25% / 66.45% 4”/7” Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 28 5/8" W x 25 3/8" H Ceramic Heater 33” 36" 18 1/16” - - - Yes
ZCV34LPH/ZCV34LPHE Propane Top Millivolt / IPI 18,000 BTU 14,000 BTU 66.38% / 69.25% 4”/7” Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 28 5/8" W x 25 3/8" H Ceramic Heater 33” 36” 18 1/16” - - - Yes

ZCV39N

Model Fuel Flue Gas Control Input Max. Input Min. FE (p.4.1-02)% Venting Viewing Area Glass Type Certification Actual Width (CVCK) Actual Height (CVCK) Actual Depth (CVCK) Actual Width (Louvers) Actual Height (Louvers) Actual Depth (Louvers) Power Vent
ZCV39N/NE Natural Top Millivolt / IPI 25,000 BTU 16,750 BTU 52.35% / 54.24% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 33" W x 28 5/8" H Tempered Heater 39 3/8" 37 11/16” 18 7/16" - - - Yes
ZCV39LP/LPE Propane Top Millivolt / IPI 25,000 BTU 20,000 BTU 52.35% / 54.24% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 33" W x 28 5/8" H Tempered Decorative 39 3/8" 37 11/16” 18 7/16” - - - Yes
ZCV39NH/NHE Natural Top Millivolt / IPI 28,000 BTU 19,000 BTU 63.81% / 66.17% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 33" W x 28 5/8" H Ceramic Heater 39 3/8" 37 11/16” 18 7/16" - - - Yes
ZCV39LPH/LPHE Propane Top Millivolt / IPI 29,000 BTU 23,000 BTU 66.82% / 68.65% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 33" W x 28 5/8" H Ceramic Heater 39 3/8" 37 11/16” 18 7/16" - - - Yes

ZCV42

Model Fuel Flue Gas Control Input Max. Input Min. FE (p.4.1-02)% Venting Viewing Area Glass Type Certification Actual Width (CVCK) Actual Height (CVCK) Actual Depth (CVCK) Actual Width (Louvers) Actual Height (Louvers) Actual Depth (Louvers) Power Vent
ZCV42N/NE Natural Top Millivolt / IPI 25,000 BTU 16,500 BTU 52.86% / 54.95% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 37 1/8" W x 31 3/4" H Tempered Heater 42 7/16" 40 7/8" 18 7/16" - - - Yes
ZCV42LP/LPE Propane Top Millivolt / IPI 25,000 BTU 19,500 BTU 52.86% / 54.95% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 37 1/8" W x 31 3/4" H Tempered Heater 42 7/16" 40 7/8" 18 7/16" - - - Yes
ZCV42NH/NHE Natural Top Millivolt / IPI 29,500 BTU 20,000 BTU 64.53% / 66.48% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 37 1/8" W x 31 3/4" H Ceramic Heater 42 7/16" 40 7/8" 18 7/16" - - - Yes
ZCV42LPH/LPHE Propane Top Millivolt / IPI 29,000 BTU 23,000 BTU 66.65% / 68.77% 4/7" Flex or 4 x 6 5/8 Hard Pipe* or Power Vent 37 1/8" W x 31 3/4" H Ceramic Heater 42 7/16" 40 7/8" 18 7/16" - - - Yes

Flame Displays

LOGF3
LOGC44
Cannonballs
Decorative Ember Glass

Brick Liners

Herringbone
Red Herringbone
Stacked
Traditional

Please view the brochure for all available styling options for each specific appliance.

REMOTE CONTROL

(for IPI PF2 models only).
Features flame height modulation and multi-color LED accent lighting control.